Version 1.0 2010/08311-4277100-007MANUALOWNER'SBlood Glucose Monitoring System

Pagina 2

10Display Screen Test Result Ketone Warning Error Message Memory Mode Symbol Control Solution Mode Measuring Mode Blood Drop Symbol Test Strip Symb

Pagina 3 - READ BEFORE USE

11Test Strip Test results might be wrong if the contact bar is not fully inserted into the test slot.Attention!The front side of the test strip should

Pagina 4 - TABLE OF CONTENTS

12Setting the Meter Before using your meter for the rst time or if you change the meter battery, you should check and update these settings. Make sur

Pagina 5

132. Setting the time format Press the M button to select the desired time format --- 12h or 24h. Press SET.3. Setting the time With the hour ashing,

Pagina 6 - BEFORE YOU BEGIN

145. Setting the reminder alarmYou may set up any or all of the reminder alarms (1-4). The meter displays “On” or “OFF” and , press the M button to

Pagina 7 - Test Principle

15THE FOUR MEASURING MODES The meter provides you with four modes for measuring General, AC, PC and QC.2. Press the M button to switch between General

Pagina 8 - Contents of System

16Control Solution Testing UltraTRAK Control Solution contains a known amount of glucose that reacts with test strips and is used to ensure your meter

Pagina 9 - Meter Overview

173. Apply Control Solution.Shake the control solution vial thoroughly before use. Squeeze out a drop and wipe it off, then squeeze ano

Pagina 10 - Display Screen

18Out-of-range results If you continue to have test results fall outside the range printed on the test strip vial, the meter and strips may not be wor

Pagina 11 - Test Strip

19GETTING A BLOOD SAMPLE Overview of the Lancing DeviceSetting up the Lancing DeviceIf your lancing device differs from the one shown above, please r

Pagina 12 - Setting the Meter

Dear UltraTRAK Ultimate System Owner:Thank you for purchasing the UltraTRAK Ultimate Blood Glucose Monitoring System. This manual provides

Pagina 13

203. Twist the protective disk off the lancet. 4. Replace the cap by aligning the arrow on the cap with the release button. 5. Select the depth of

Pagina 14

21Preparing the Puncture Site.Stimulating blood perfusion by rubbing the puncture site before blood extraction has a signicant inuence on the glucos

Pagina 15 - THE FOUR MEASURING MODES

22Performing a Blood Glucose Test 1. Insert the Test Strip to Turn on the MeterWait for the meter to display the test strip and blood drop

Pagina 16 - BEFORE TESTING

234. Apply the Sample Hold the blood drop to touch the absorbent hole of the test strip. Blood will be drawn in and after the conrmation window

Pagina 17

245.Read the ResultThe result of your blood glucose test will appear after the meter counts to 0. This reading will automatically be stored in

Pagina 18

25METER MEMORY Reviewing Test Results The meter stores the 1000 most recent blood glucose test results along with respective dates and

Pagina 19 - GETTING A BLOOD SAMPLE

26Reviewing Blood Glucose Day Average Results 1. Press and release the M button When appears on the display, keep pressing the M button for 3 seconds

Pagina 20

272. Exit the meter memory Keep pressing the M button and the meter will turn off after display-ing the last test result. Any time you wish to ex

Pagina 21 - Preparing the Puncture Site

28Downloading Results onto a Computer You can use the meter with a USB cable and the Health Care Software System to view your test results on your per

Pagina 22

29MAINTENANCE Battery Your meter comes with two1.5V AAA size alkaline batteries.1. The symbol appears along with display messages: The meter

Pagina 23

IMPORTANT SAFETY PRECAUTIONSREAD BEFORE USE1. Use the device only for the intended use described in this manual.2. Do not use accessories which are no

Pagina 24

30 Replacing the batteries does not affect the test results stored in memory. As with all small batteries, these batteries should be k

Pagina 25 - METER MEMORY

31Caring for Your Meter To avoid the meter and test strips attracting dirt, dust or other contaminants, please wash and dry your hands thor

Pagina 26

32Important Control Solution Information Use only UltraTRAK control solutions with your meter. Do not use the control solution beyond the ex

Pagina 27

33SYSTEM TROUBLESHOOTING If you follow the recommended action but the problem persists, or error messages other than the ones below appear,

Pagina 28

34Error Messages MESSAGE WHAT IT MEANS WHAT TO DOAppears when the batteries cannot provide enough power for a test.Replace the batteries immediately

Pagina 29 - MAINTENANCE

35Troubleshooting 1. If the meter does not display a message after inserting a test strip:2. If the test does not start after applying the sample:3. I

Pagina 30

36DETAILED INFORMATION Reference Values Blood glucose monitoring plays an important role in diabetes control. A long-term study showed that maintainin

Pagina 31 - Caring for Your Test Strips

37Comparing Meter and Laboratory Results The meter provides you with plasma equivalent results. The result you obtain from your meter may differ

Pagina 32

38References *2: Surwit, R.S., and Feinglos, M.N.: Diabetes Forecast (1988), April, 49-51.*3: Sacks, D.B.: “Carbohydrates. “ Burtis, C.A., and Ashwood

Pagina 33 - SYSTEM TROUBLESHOOTING

39SPECIFICATIONS Model No.: UTUBGMDimension & Weight: 96 (L) x 61 (W) x 26 (H) mm, 67.2 g Power source: Two 1.5V AAA alkaline batteries Display: L

Pagina 34 - Error Messages

TABLE OF CONTENTSIMPORTANT SAFETY PRECAUTIONS 3BEFORE YOU BEGIN 6Important Information 6Intended Use 7Test Principle 7Contents of System 8Meter

Pagina 36 - DETAILED INFORMATION

Battery 29 Caring for Your Meter 31Caring for Your Test Strips 31Important Control Solution Information 32SYSTEM TROUBLESHOOTING 33Result Read

Pagina 37

6Important Information Severe dehydration and excessive water loss may cause readings ►which are lower than actual values. If you believe you are suf

Pagina 38

7Intended Use This system is intended for use outside the body (in vitro diagnostic use) by people with diabetes at home and by health care profession

Pagina 39 - SPECIFICATIONS

8Contents of System Your new UltraTRAK Ultimate system kit includes:For replacing test strips, control solutions, and sterile lancets please contact y

Pagina 40

9Meter Overview TEST STRIP EJECTOREject the used strip by pushing this button up. DISPLAY SCREEN M BUTTONEnter the meter memory and silence a remind